AMPROBE INSTRUMENT DM-II DATA LOGGER
ACD-330T TRUE RMS CLAMP-ON |
DM-II PRO DATA LOGGER
The New DigiMatic II(TM) is an AC Data/Logger Recorder in a stand alone configuration,
Data can be viewed in the field via its large self-contained backlit LCD Display
or can be accessed and downloaded to a personal computer.
- Single or three phase capable
- AC voltage 5 to 600 volts
- AC current 1 to 1000 amperes
- 3 channels for voltage measurements and
4 channels for current measurements
- Graphic display 160 x 160 pixel
- All readings are True RMS
- Power Measurements include:
- Watts
- Vars
- VA
- PF(Power Factor)
- Energy Measurements include:
- KW-HR's
- Demand or Non-Demand
- User selectable recording rates
- DM-II View (TM) software allows downloading data to a personal computer
running Windows 3.1 or 95. Computer requirements: 486 - 50 MHz, 8MB of Ram (16 MB
recommended)
- Line Operated (120V/60Hz & 240V/50Hz)
- Battery backup protects memory if a power failure occurs and allows
recording session to continue
- Auto Ranging
- Real time clock
- Multi Languages including Eng., Ger., Span., Italian, French
- Rugged ABS plastic case with a weather resistant design
- Made in USA
ACD-330T TRUE RMS CLAMP-ON
Just as Amprobe's famous RS series fulfilled the electrical contractor's
needs for a reliable and rugged instrument over 40 years ago, the ACD-330T
was designed to meet the contractor's needs of today - and into the next century.
As the number of non-linear loads increase, so does the requirement of an instrument
with the ability to measure and display True RMS values. Non-linear loads, or loads
that do not draw a sinusoidal current, can cause an average sensing instrument
(calibrated to display RMS of a sinewave) to display inaccurate results. The ACD-330T
provides the user with the ability to accurately measure True RMS AC Current to 1000A
and True RMS AC Voltage to 1000V. The dual display enables the Frequency up to 1kHz
to be displayed simultaneously during current measurements (through the jaw) or during
voltage measurements (through the test probes). By entering the dynamic recording mode,
which disables the auto power off feature, Maximum, Average, and Minimum values of all
parameters for the selected range can be recorded. The PEAK mode provides the ability
to capture peak inrush current or voltage glitches with a duration of 1 millisecond
or more. DC voltage to 1000V and Resistance to 4 kOhms are also featured. Other
features include:
- True RMS AC Current Measurement to 1000A
- True RMS AC and DC Voltage Measuremnt to 1000V
- Frequency measurement to 1KHz
- Dual Display for Frequency & Current or Frequency & Voltage
- Resistance Measurement up to 4 kOhms
- Dynamic Min/Max/Avg. Recording
- PEAK Hold (1 ms response)
- Designed to conform to UL, ULc, TUV, CE, IEC Standards
- Overload Protection On All Ranges
- Auto/Manual Ranging
- Auto Power Off
- Sleep Mode
- Data Hold
- Audible and Visual Continuity Indicator
- Fully Annunciated 4000 Count, 4 Digit LCD
- Auto Relative/Zero Reference Button
- Low Battery Indicator
- Drop Proof
- Diode Check
- 12 Segment Analog Bargraph
Click here for